For raw-material manufacturers (and their authorized distributors) who want to publish Material Dossiers.
This guide is practical; where it and SPEC.md differ, SPEC.md is right.
All examples here are invented.
1. What you publish
One JSON file per sellable grade: each product code gets its own dossier. A solution and a powder of the same
active, or three viscosity grades of one polymer, are separate dossiers; put the family name in identity.family.
You publish it on your own domain, list it in an index file, and update it by issuing a new version. Software at your customers reads it. You are responsible for the content; consumers check the structure, not the truth.
You can start small. Level 1 needs only the identity and the use data of the material. Level 2 is the content of a technical data sheet. Level 3 replaces the brochure, with the numbers behind every graph.
2. The skeleton
{
"standard_version": "1.0",
"vocab_version": "1.0",
"dossier_id": "example.com:exagel-r200",
"version": 1,
"issued": "2026-11-02T09:00:00Z",
"representation": "public",
"completeness": "partial",
"conformance_level": "L1",
"default_language": "en",
"source": { "route": "manufacturer", "publisher": { "name": "Example Ingredients Ltd.", "domain": "example.com" } },
"identity": { "trade_name": "Exagel R200", "product_code": "EX-2200",
"manufacturer": { "name": "Example Ingredients Ltd.", "domain": "example.com", "country": "IE" },
"inci": ["Acrylates/C10-30 Alkyl Acrylate Crosspolymer"], "as_of": "2026-05" },
"properties": [], "statements": []
}
The skeleton becomes a valid Level 1 dossier once the use data of section 3.4 are added.
dossier_idis your domain, a colon and a name you choose. It never changes and is never reused.versiongoes up with every change you publish. From version 2 on,supersedesnames the previous version and its hash.- Every element you add needs an
id(your choice, stable across versions) and anas_ofdate: when the data were established, not when you typed them.
3. From brochure to dossier, section by section
3.1 Header of the data sheet → identity
| On the data sheet | In the dossier |
|---|---|
| Trade name | identity.trade_name |
| Product number | identity.product_code |
| "Powder grade", "30 % solution" | identity.grade |
| INCI name(s) | identity.inci[], CosIng spelling, descending by content. US or China names: inci_variants[] |
| CAS, EC numbers | identity.cas[], identity.ec[] (and per component in composition) |
| Chemical name, formula | chemical_name, molecular_formula |
| Structural formula drawing | a media element of kind structure |
3.2 Composition statement → composition
One component per INCI name, with a role and a content.
{ "id": "c-betaine", "inci": "Betaine", "cas": ["107-43-7"], "role": "active",
"content": { "range": { "min": 12, "max": 16 } },
"origin": { "type": "plant", "botanical": { "latin_name": "Beta vulgaris", "plant_part": "root" } } }
- "28.5–32.0 %" is a
range; "max. 0.1 %" is{ "limit": { "op": "<=", "value": 0.1 } }; "n.d." in an allergen table is{ "nominal": "not_detected" }. - Preservatives, antioxidants, solvents and carriers are components too (
role). - If you do not want the exact composition public, publish ranges publicly and the exact values in the restricted representation (section 6).
- Plant origin, plant part, country, extraction solvent and drug–extract ratio go into
origin.botanical. - ISO 16128 indexes are properties (3.9), not part of the composition.
3.3 Specification and typical data → properties
Each row of the table is one property.
| On the data sheet | key | basis | value, unit |
|---|---|---|---|
| Appearance: white powder | physchem.appearance | specification | { "text": { "en": "White powder" } } |
| pH (10 % in water, 20 °C): 5.0–6.5 | physchem.ph | specification | range 5.0–6.5, [pH]; subject = dilution 10 % in water; condition temperature 20 Cel |
| Viscosity (0.5 %, 20 rpm, 25 °C): 40 000–60 000 mPa·s | rheology.viscosity | specification | range, mPa.s; subject = dilution; method.settings rotation speed; condition temperature |
| Acid value: max. 0.1 mg KOH/g | physchem.acid_value | specification | limit <= 0.1, mg{KOH}/g |
| Lead: < 1 ppm | purity.lead | specification | limit < 1, [ppm] |
| Total viable count: < 100 cfu/g | micro.total_aerobic_count | specification | limit < 100, [CFU]/g |
| Density (20 °C): approx. 1.12 g/cm³ — "typical, not part of the specification" | physchem.density | typical | exact 1.12, g/cm3 |
| Shelf life: 24 months | stability.shelf_life | specification | exact 24, mo |
Three members matter most:
basissays in what sense the number holds:specification(guaranteed),typical,measured(one test),recommended(your advice),regulatory_limit,calculated,declared.subjectsays what was measured: the material as supplied (neat), a dilution (medium and concentration), a formulation of this dossier, a biological system, or another material.valuehas exactly one form. Uselimitfor "max.", "min.", "<", ">", "up to". Never write a limit as an exact number.
Put the measuring conditions where they belong: the standard in method.standard (iso:2555, ph-eur:2.2.3),
the instrument and its settings in method, temperature and the like in conditions. A footnote such as "all
viscosities measured at 25 °C, 20 rpm" has to be repeated on every property it applies to.
3.4 "Use" paragraph → the usage view
This is the part formulation software checks formulas against. It is also all that Level 1 needs.
| On the data sheet | In the dossier |
|---|---|
| "Recommended use level 1–5 %" | use.level, basis recommended, subject neat, range 1–5, % |
| "up to 5 %" | the same with { "limit": { "op": "<=", "value": 5 } } |
| "typically 3 %" | use.level_typical, exact 3 |
| "2–8 % in rinse-off products" | a second use.level with scope.product_type: ["rinse_off"] |
| "add to the water phase" / "oil phase" / "below 40 °C at the end" | use.phase with water_phase / oil_phase / cool_down; one property per allowed stage |
| "for formulations of pH 4–8" | use.ph_window, range 4–8, [pH] |
| "do not heat above 60 °C" | use.process_temperature_max, limit <= 60, Cel |
| "EU: max. 10 %" | use.level, basis regulatory_limit, scope.region: ["EU"], with its own as_of |
| Processing advice in sentences | statements of kind guidance (at most 300 characters each; the first six count) |
| Questions a reviewer should ask of a formula | statements of kind checklist ("Is a neutralizer present?") |
Only one use level may be "general" (no scope, no conditions). Everything specific to a product type, a region or a
condition gets a scope or conditions.
3.5 Functions, form, solubility, HLB, sensory → profile
One property each, with a code from the vocabulary:
{ "id": "fn-humectant", "as_of": "2026-03", "key": "profile.function", "basis": "declared",
"subject": { "kind": "neat" }, "value": { "nominal": "humectant" } }
profile.function (CosIng function names), profile.application (product types), profile.physical_form,
profile.ionic_character, profile.hlb, profile.required_hlb, solubility.water, solubility.oil,
sensory.descriptor. Marketing adjectives that have no code stay in a benefit statement.
3.6 Graphs → datasets
Publish the numbers behind the graph and the picture.
{ "id": "ds-visc-conc", "as_of": "2026-05", "title": { "en": "Viscosity against polymer concentration" },
"basis": "typical", "points_origin": "publisher_raw", "figure": "fig-visc-conc",
"subject": { "kind": "dilution", "medium": "deionized water, neutralized to pH 6.5" },
"method": { "standard": "iso:2555", "settings": [ { "key": "rotation_speed", "value": 20, "unit": "{rpm}" } ] },
"conditions": [ { "key": "temperature", "value": 25, "unit": "Cel" } ],
"axes": [ { "key": "material_concentration", "type": "numeric", "unit": "%", "scale": "lin", "role": "independent" },
{ "key": "rheology.viscosity", "type": "numeric", "unit": "mPa.s", "scale": "log", "role": "dependent" } ],
"series": [ { "id": "ser-conc", "label": { "en": "Exagel R200" },
"points": [[0.1, 1200], [0.2, 9500], [0.5, 51000], [1.0, 79000]] } ] }
- Several curves in one graph are several
series, each with the condition that distinguishes it. - Tables with "+", "++", "good / very good" are datasets with an ordinal axis and a
legend; do not turn them into numbers. - If you only have the picture, publish it with
points_origin: "none". That is allowed up to Level 2. Level 3 needs the numbers.
3.7 Studies → studies, formulations, properties
- Describe the study once: kind (
in_vivo,ex_vivo,in_vitro,in_silico,consumer_perception,sensory_panel, …), design, number of subjects, duration, application, laboratory. - Describe each arm as a formulation (test formula, placebo, benchmark) with all lines and percentages. Mark
your material's line with
is_subject: true. - Give each result as a property that references the study and the formulation:
{ "id": "eff-hydration", "as_of": "2024-02", "key": "efficacy.hydration", "basis": "measured",
"subject": { "kind": "formulation", "formulation": "f-test" }, "study": "st-hydration",
"method": { "name": "Corneometry", "non_standard": true },
"conditions": [ { "key": "time_point", "value": 672, "unit": "h" } ],
"value": { "exact": 24.1 }, "unit": "%",
"comparison": { "vs": "placebo", "ref": "f-placebo", "change": "relative" },
"statistics": { "n": 24, "p": { "op": "<", "value": 0.01 }, "significant": "yes" },
"outcome": "positive" }
- Publish the results without effect too (
outcome: "no_effect",significant: "no"). They are what makes the positive ones credible, and Level 3 requires that you state all endpoints are reported. - Self-assessment questionnaires ("87 % agreed that…") are a
consumer_perceptionstudy withconsumer.agreementresults. Do not mix them with instrumental results. Market research ("72 % of consumers want…") is not a study and does not belong in a dossier. - A result obtained on a sister product needs
read_across_from.
3.8 Sunscreen data
SPF, UVA-PF, critical wavelength, water resistance and SPF boost are results of a test formulation, never of the filter or booster itself. The rules are strict:
- the property's subject is the formulation;
- the formulation lists every UV filter and booster with its percentage and names the base (
product_form); - the method standard is given (
iso:24444,iso:24443, …); - an SPF boost names the comparator formulation.
"Boosts SPF by 50 %" without the formulation cannot be published as a value. It can only be a claim statement,
and consumers will show it as an unsupported claim.
Add a disclaimer statement that these results do not transfer to other products. Your customers still need their own tests for their own product (Recommendation 2006/647/EC, Regulation (EU) No 655/2013).
3.9 Compatibility → relations
{ "id": "rel-cationic", "as_of": "2026-05", "with": { "class": "cationic_surfactants" },
"effect": "incompatible", "basis": "declared" }
Name the partner by class (vocabulary interaction-classes) or by INCI. Give the condition when there is one
("above 0.5 % sodium chloride"). If you measured it, point to the property or dataset in support.
3.10 Safety data → properties with tox.*, and the SDS as a document
Selected values only: acute toxicity, irritation, sensitisation, phototoxicity, mutagenicity, HRIPT. Each with the
guideline (oecd:439) and the test concentration. Do not copy the SDS; reference it as a media element of kind
source_document with document kind sds. Leave "no data available" rows out.
3.11 Regulatory status, certificates, declarations → attestations
| Document | In the dossier |
|---|---|
| "Listed in IECIC 2021" | scheme cn_iecic, status listed, scope.region: ["CN"], edition |
| REACH registered | scheme eu_reach, status registered |
| COSMOS approval, valid for one year | scheme cosmos, status approved, issuer, certificate_id, valid_from, valid_until, usage_restriction |
| Vegan, GMO-free, BSE/TSE, CMR declarations | one attestation each (vegan, gmo_free, bse_tse_free, cmr_free), status compliant or free_of |
| IFRA certificate | scheme ifra, edition (the amendment), limits[] per category with max or prohibited |
| ISO 16128 letter | attestation iso_16128 plus properties origin.natural_origin_index etc. with method.standard: "iso:16128-2" |
Always give valid_until for certificates, and say in usage_restriction what your customer may not do with the
certificate (for example no_customer_reference).
3.12 Starting formulations → formulations
Role starting_formula, all lines with phase, INCI, percent (one line may be qs), your material marked
is_subject, the procedure as steps. Measured data of the formulation (pH, viscosity, stability, SPF) are
properties with the formulation as subject.
3.13 Descriptions, benefits, claims → statements
Free text is for people. Software that consumes dossiers shows it and does not act on it. So: whatever you want
formulation software to use must also be present as a property, relation or attestation. A claim should point to
the results behind it in supports.
4. Numbers and units
- JSON numbers with a decimal point. No thousands separators, no units, no "<" inside the number.
- Units are UCUM codes:
%,[ppm],mPa.s,Cel,[pH],mo,g/cm3,[CFU]/g,nm,1(no unit). Each key lists its accepted units invocab/property-keys.jsonandvocab/units.json; prefer the canonical one. - Keep the original wording in
as_writtenif you like ("40 000 – 60 000 mPa·s"). - Dates:
2026,2026-05or2026-05-17.
5. Publishing
- Put each dossier on your web server over HTTPS, at a URL that does not change for that version, for example
https://example.com/material-dossier/exagel-r200/v1.json. - Compute its SHA-256 (
sha256sum v1.json). - List it in
https://example.com/.well-known/material-dossier/index.json:
{ "standard": "rubedyne-material-dossier", "standard_versions": ["1.0"],
"publisher": { "name": "Example Ingredients Ltd.", "domain": "example.com", "role": "manufacturer" },
"updated": "2026-11-02T09:00:00Z",
"dossiers": [ { "dossier_id": "example.com:exagel-r200", "trade_name": "Exagel R200", "product_code": "EX-2200",
"version": 1, "updated": "2026-11-02T09:00:00Z", "status": "active", "route": "manufacturer",
"conformance_level": "L3", "standard_version": "1.0", "vocab_version": "1.0",
"public": { "url": "https://example.com/material-dossier/exagel-r200/v1.json",
"hash": "sha256:…" } } ] }
- To change something: issue version 2 as a new file, update the index entry. Never edit a published version.
- To retire a grade: set
status: "withdrawn"and keep the entry for a year. - Figures: PNG, JPEG or WebP at stable URLs, with their SHA-256 and a licence that lets consumers store and show
them (
redistribution: "consumer_display"at least). No SVG. - If distributors publish your dossiers, list their domains in
authorized_publishers.
6. Public and restricted content
Mark anything you only share with partners with visibility: "restricted". You then serve two files per version:
- the public one, without any restricted element;
- the restricted one, with everything, behind
Authorization: Bearer <token>.
Typical: public composition in ranges, exact composition restricted (refines); public study summary as
properties, full report restricted. A public element must not point to a restricted one.
7. Common mistakes
| Mistake | Instead |
|---|---|
"value": { "exact": 5 } for "up to 5 %" | limit with <= |
| A regulatory maximum published as the recommended use level | separate properties with different basis |
Typical data labelled specification | basis: "typical" |
| Viscosity without concentration, medium, temperature or speed | subject as dilution, conditions, method.settings |
| One "general" value where the source gives several by product type or pH | several properties with scope or conditions |
| SPF published against the raw material | tie it to the test formulation |
| Concentration without saying of what | material_conc.basis: as_supplied, active or total_solids |
| Numbers read off your own graph by eye | publish the raw series, or mark the figure as having no data |
| Only the positive endpoints of a study | all endpoints, with outcome |
| Certificate without validity | valid_from, valid_until |
Today's date as as_of on five-year-old test data | the date of the test |
| Batch values from a certificate of analysis | leave them out; a dossier is not batch data |
| A key that does not exist, slightly misspelled | check vocab/; for a genuinely new key use x-yourdomain.com:name and propose it |
Text in a number field ("n/a", "-") | leave the element out |
| Instructions or links in free text | plain sentences; consumers strip and escape them anyway |
| Editing a published version | new version |
8. Conformance checklist
Run .venv/bin/python tools/check_dossier.py path/to/your-dossier.json from the repository root (setup: README,
"Checking a dossier"); it reports the level your dossier reaches and what is missing for the next one.
Level 1 — Core
- Valid against the schema; all keys in the vocabularies.
-
identity: trade name, product code, manufacturer, INCI. - One general recommended
use.levelwith an upper bound. - At least one
use.phase(water phase, oil phase, cool-down, added to the hot water phase, added to the hot oil phase), orcold_processfor a material that is processed only without heating. - Recommended:
use.level_typical,use.ph_window,use.process_temperature_max, a fewguidancelines. - Every element has
idandas_of. - Listed in your index with its hash.
Level 2 — Technical (the data sheet)
- Level 1.
-
composition: every component with role and content. - At least one
profile.functionand theprofile.physical_form. - The specification: at least three properties with basis
specificationortypical(in practice: all rows of your specification table). -
stability.shelf_lifeorstability.retest_period. - Regulatory status for at least one region as an attestation.
- The SDS referenced as a source document.
- Certificates with validity dates and usage restrictions.
- Graphs present at least as figures, marked
points_origin: "none"when without data.
Level 3 — Complete (replaces the brochure)
- Level 2.
- Every graph has its numeric (or ordinal) series.
- No value exists only in a figure.
- Every study: laboratory, number of subjects, at least one structured result,
all_endpoints_reported: true. - Every efficacy result states whether it was significant.
-
declarations.negative_results_included: true. -
completeness: "full". - Sunscreen and efficacy results tied to fully described test formulations.