Material Dossier standard

Publisher guide

For raw material manufacturers and distributors: how to turn a brochure or TDS into a dossier, field by field.

Public draft, for feedbackVersion 1.0.0-draft.7

For raw-material manufacturers (and their authorized distributors) who want to publish Material Dossiers. This guide is practical; where it and SPEC.md differ, SPEC.md is right.

All examples here are invented.

1. What you publish

One JSON file per sellable grade: each product code gets its own dossier. A solution and a powder of the same active, or three viscosity grades of one polymer, are separate dossiers; put the family name in identity.family.

You publish it on your own domain, list it in an index file, and update it by issuing a new version. Software at your customers reads it. You are responsible for the content; consumers check the structure, not the truth.

You can start small. Level 1 needs only the identity and the use data of the material. Level 2 is the content of a technical data sheet. Level 3 replaces the brochure, with the numbers behind every graph.

2. The skeleton

{
  "standard_version": "1.0",
  "vocab_version": "1.0",
  "dossier_id": "example.com:exagel-r200",
  "version": 1,
  "issued": "2026-11-02T09:00:00Z",
  "representation": "public",
  "completeness": "partial",
  "conformance_level": "L1",
  "default_language": "en",
  "source": { "route": "manufacturer", "publisher": { "name": "Example Ingredients Ltd.", "domain": "example.com" } },
  "identity": { "trade_name": "Exagel R200", "product_code": "EX-2200",
                "manufacturer": { "name": "Example Ingredients Ltd.", "domain": "example.com", "country": "IE" },
                "inci": ["Acrylates/C10-30 Alkyl Acrylate Crosspolymer"], "as_of": "2026-05" },
  "properties": [], "statements": []
}

The skeleton becomes a valid Level 1 dossier once the use data of section 3.4 are added.

  • dossier_id is your domain, a colon and a name you choose. It never changes and is never reused.
  • version goes up with every change you publish. From version 2 on, supersedes names the previous version and its hash.
  • Every element you add needs an id (your choice, stable across versions) and an as_of date: when the data were established, not when you typed them.

3. From brochure to dossier, section by section

3.1 Header of the data sheet → identity

On the data sheetIn the dossier
Trade nameidentity.trade_name
Product numberidentity.product_code
"Powder grade", "30 % solution"identity.grade
INCI name(s)identity.inci[], CosIng spelling, descending by content. US or China names: inci_variants[]
CAS, EC numbersidentity.cas[], identity.ec[] (and per component in composition)
Chemical name, formulachemical_name, molecular_formula
Structural formula drawinga media element of kind structure

3.2 Composition statement → composition

One component per INCI name, with a role and a content.

{ "id": "c-betaine", "inci": "Betaine", "cas": ["107-43-7"], "role": "active",
  "content": { "range": { "min": 12, "max": 16 } },
  "origin": { "type": "plant", "botanical": { "latin_name": "Beta vulgaris", "plant_part": "root" } } }
  • "28.5–32.0 %" is a range; "max. 0.1 %" is { "limit": { "op": "<=", "value": 0.1 } }; "n.d." in an allergen table is { "nominal": "not_detected" }.
  • Preservatives, antioxidants, solvents and carriers are components too (role).
  • If you do not want the exact composition public, publish ranges publicly and the exact values in the restricted representation (section 6).
  • Plant origin, plant part, country, extraction solvent and drug–extract ratio go into origin.botanical.
  • ISO 16128 indexes are properties (3.9), not part of the composition.

3.3 Specification and typical data → properties

Each row of the table is one property.

On the data sheetkeybasisvalue, unit
Appearance: white powderphyschem.appearancespecification{ "text": { "en": "White powder" } }
pH (10 % in water, 20 °C): 5.0–6.5physchem.phspecificationrange 5.0–6.5, [pH]; subject = dilution 10 % in water; condition temperature 20 Cel
Viscosity (0.5 %, 20 rpm, 25 °C): 40 000–60 000 mPa·srheology.viscosityspecificationrange, mPa.s; subject = dilution; method.settings rotation speed; condition temperature
Acid value: max. 0.1 mg KOH/gphyschem.acid_valuespecificationlimit <= 0.1, mg{KOH}/g
Lead: < 1 ppmpurity.leadspecificationlimit < 1, [ppm]
Total viable count: < 100 cfu/gmicro.total_aerobic_countspecificationlimit < 100, [CFU]/g
Density (20 °C): approx. 1.12 g/cm³ — "typical, not part of the specification"physchem.densitytypicalexact 1.12, g/cm3
Shelf life: 24 monthsstability.shelf_lifespecificationexact 24, mo

Three members matter most:

  • basis says in what sense the number holds: specification (guaranteed), typical, measured (one test), recommended (your advice), regulatory_limit, calculated, declared.
  • subject says what was measured: the material as supplied (neat), a dilution (medium and concentration), a formulation of this dossier, a biological system, or another material.
  • value has exactly one form. Use limit for "max.", "min.", "<", ">", "up to". Never write a limit as an exact number.

Put the measuring conditions where they belong: the standard in method.standard (iso:2555, ph-eur:2.2.3), the instrument and its settings in method, temperature and the like in conditions. A footnote such as "all viscosities measured at 25 °C, 20 rpm" has to be repeated on every property it applies to.

3.4 "Use" paragraph → the usage view

This is the part formulation software checks formulas against. It is also all that Level 1 needs.

On the data sheetIn the dossier
"Recommended use level 1–5 %"use.level, basis recommended, subject neat, range 1–5, %
"up to 5 %"the same with { "limit": { "op": "<=", "value": 5 } }
"typically 3 %"use.level_typical, exact 3
"2–8 % in rinse-off products"a second use.level with scope.product_type: ["rinse_off"]
"add to the water phase" / "oil phase" / "below 40 °C at the end"use.phase with water_phase / oil_phase / cool_down; one property per allowed stage
"for formulations of pH 4–8"use.ph_window, range 4–8, [pH]
"do not heat above 60 °C"use.process_temperature_max, limit <= 60, Cel
"EU: max. 10 %"use.level, basis regulatory_limit, scope.region: ["EU"], with its own as_of
Processing advice in sentencesstatements of kind guidance (at most 300 characters each; the first six count)
Questions a reviewer should ask of a formulastatements of kind checklist ("Is a neutralizer present?")

Only one use level may be "general" (no scope, no conditions). Everything specific to a product type, a region or a condition gets a scope or conditions.

3.5 Functions, form, solubility, HLB, sensory → profile

One property each, with a code from the vocabulary:

{ "id": "fn-humectant", "as_of": "2026-03", "key": "profile.function", "basis": "declared",
  "subject": { "kind": "neat" }, "value": { "nominal": "humectant" } }

profile.function (CosIng function names), profile.application (product types), profile.physical_form, profile.ionic_character, profile.hlb, profile.required_hlb, solubility.water, solubility.oil, sensory.descriptor. Marketing adjectives that have no code stay in a benefit statement.

3.6 Graphs → datasets

Publish the numbers behind the graph and the picture.

{ "id": "ds-visc-conc", "as_of": "2026-05", "title": { "en": "Viscosity against polymer concentration" },
  "basis": "typical", "points_origin": "publisher_raw", "figure": "fig-visc-conc",
  "subject": { "kind": "dilution", "medium": "deionized water, neutralized to pH 6.5" },
  "method": { "standard": "iso:2555", "settings": [ { "key": "rotation_speed", "value": 20, "unit": "{rpm}" } ] },
  "conditions": [ { "key": "temperature", "value": 25, "unit": "Cel" } ],
  "axes": [ { "key": "material_concentration", "type": "numeric", "unit": "%", "scale": "lin", "role": "independent" },
            { "key": "rheology.viscosity", "type": "numeric", "unit": "mPa.s", "scale": "log", "role": "dependent" } ],
  "series": [ { "id": "ser-conc", "label": { "en": "Exagel R200" },
                "points": [[0.1, 1200], [0.2, 9500], [0.5, 51000], [1.0, 79000]] } ] }
  • Several curves in one graph are several series, each with the condition that distinguishes it.
  • Tables with "+", "++", "good / very good" are datasets with an ordinal axis and a legend; do not turn them into numbers.
  • If you only have the picture, publish it with points_origin: "none". That is allowed up to Level 2. Level 3 needs the numbers.

3.7 Studies → studies, formulations, properties

  1. Describe the study once: kind (in_vivo, ex_vivo, in_vitro, in_silico, consumer_perception, sensory_panel, …), design, number of subjects, duration, application, laboratory.
  2. Describe each arm as a formulation (test formula, placebo, benchmark) with all lines and percentages. Mark your material's line with is_subject: true.
  3. Give each result as a property that references the study and the formulation:
{ "id": "eff-hydration", "as_of": "2024-02", "key": "efficacy.hydration", "basis": "measured",
  "subject": { "kind": "formulation", "formulation": "f-test" }, "study": "st-hydration",
  "method": { "name": "Corneometry", "non_standard": true },
  "conditions": [ { "key": "time_point", "value": 672, "unit": "h" } ],
  "value": { "exact": 24.1 }, "unit": "%",
  "comparison": { "vs": "placebo", "ref": "f-placebo", "change": "relative" },
  "statistics": { "n": 24, "p": { "op": "<", "value": 0.01 }, "significant": "yes" },
  "outcome": "positive" }
  • Publish the results without effect too (outcome: "no_effect", significant: "no"). They are what makes the positive ones credible, and Level 3 requires that you state all endpoints are reported.
  • Self-assessment questionnaires ("87 % agreed that…") are a consumer_perception study with consumer.agreement results. Do not mix them with instrumental results. Market research ("72 % of consumers want…") is not a study and does not belong in a dossier.
  • A result obtained on a sister product needs read_across_from.

3.8 Sunscreen data

SPF, UVA-PF, critical wavelength, water resistance and SPF boost are results of a test formulation, never of the filter or booster itself. The rules are strict:

  • the property's subject is the formulation;
  • the formulation lists every UV filter and booster with its percentage and names the base (product_form);
  • the method standard is given (iso:24444, iso:24443, …);
  • an SPF boost names the comparator formulation.

"Boosts SPF by 50 %" without the formulation cannot be published as a value. It can only be a claim statement, and consumers will show it as an unsupported claim.

Add a disclaimer statement that these results do not transfer to other products. Your customers still need their own tests for their own product (Recommendation 2006/647/EC, Regulation (EU) No 655/2013).

3.9 Compatibility → relations

{ "id": "rel-cationic", "as_of": "2026-05", "with": { "class": "cationic_surfactants" },
  "effect": "incompatible", "basis": "declared" }

Name the partner by class (vocabulary interaction-classes) or by INCI. Give the condition when there is one ("above 0.5 % sodium chloride"). If you measured it, point to the property or dataset in support.

3.10 Safety data → properties with tox.*, and the SDS as a document

Selected values only: acute toxicity, irritation, sensitisation, phototoxicity, mutagenicity, HRIPT. Each with the guideline (oecd:439) and the test concentration. Do not copy the SDS; reference it as a media element of kind source_document with document kind sds. Leave "no data available" rows out.

3.11 Regulatory status, certificates, declarations → attestations

DocumentIn the dossier
"Listed in IECIC 2021"scheme cn_iecic, status listed, scope.region: ["CN"], edition
REACH registeredscheme eu_reach, status registered
COSMOS approval, valid for one yearscheme cosmos, status approved, issuer, certificate_id, valid_from, valid_until, usage_restriction
Vegan, GMO-free, BSE/TSE, CMR declarationsone attestation each (vegan, gmo_free, bse_tse_free, cmr_free), status compliant or free_of
IFRA certificatescheme ifra, edition (the amendment), limits[] per category with max or prohibited
ISO 16128 letterattestation iso_16128 plus properties origin.natural_origin_index etc. with method.standard: "iso:16128-2"

Always give valid_until for certificates, and say in usage_restriction what your customer may not do with the certificate (for example no_customer_reference).

3.12 Starting formulations → formulations

Role starting_formula, all lines with phase, INCI, percent (one line may be qs), your material marked is_subject, the procedure as steps. Measured data of the formulation (pH, viscosity, stability, SPF) are properties with the formulation as subject.

3.13 Descriptions, benefits, claims → statements

Free text is for people. Software that consumes dossiers shows it and does not act on it. So: whatever you want formulation software to use must also be present as a property, relation or attestation. A claim should point to the results behind it in supports.

4. Numbers and units

  • JSON numbers with a decimal point. No thousands separators, no units, no "<" inside the number.
  • Units are UCUM codes: %, [ppm], mPa.s, Cel, [pH], mo, g/cm3, [CFU]/g, nm, 1 (no unit). Each key lists its accepted units in vocab/property-keys.json and vocab/units.json; prefer the canonical one.
  • Keep the original wording in as_written if you like ("40 000 – 60 000 mPa·s").
  • Dates: 2026, 2026-05 or 2026-05-17.

5. Publishing

  1. Put each dossier on your web server over HTTPS, at a URL that does not change for that version, for example https://example.com/material-dossier/exagel-r200/v1.json.
  2. Compute its SHA-256 (sha256sum v1.json).
  3. List it in https://example.com/.well-known/material-dossier/index.json:
{ "standard": "rubedyne-material-dossier", "standard_versions": ["1.0"],
  "publisher": { "name": "Example Ingredients Ltd.", "domain": "example.com", "role": "manufacturer" },
  "updated": "2026-11-02T09:00:00Z",
  "dossiers": [ { "dossier_id": "example.com:exagel-r200", "trade_name": "Exagel R200", "product_code": "EX-2200",
                  "version": 1, "updated": "2026-11-02T09:00:00Z", "status": "active", "route": "manufacturer",
                  "conformance_level": "L3", "standard_version": "1.0", "vocab_version": "1.0",
                  "public": { "url": "https://example.com/material-dossier/exagel-r200/v1.json",
                              "hash": "sha256:…" } } ] }
  1. To change something: issue version 2 as a new file, update the index entry. Never edit a published version.
  2. To retire a grade: set status: "withdrawn" and keep the entry for a year.
  3. Figures: PNG, JPEG or WebP at stable URLs, with their SHA-256 and a licence that lets consumers store and show them (redistribution: "consumer_display" at least). No SVG.
  4. If distributors publish your dossiers, list their domains in authorized_publishers.

6. Public and restricted content

Mark anything you only share with partners with visibility: "restricted". You then serve two files per version:

  • the public one, without any restricted element;
  • the restricted one, with everything, behind Authorization: Bearer <token>.

Typical: public composition in ranges, exact composition restricted (refines); public study summary as properties, full report restricted. A public element must not point to a restricted one.

7. Common mistakes

MistakeInstead
"value": { "exact": 5 } for "up to 5 %"limit with <=
A regulatory maximum published as the recommended use levelseparate properties with different basis
Typical data labelled specificationbasis: "typical"
Viscosity without concentration, medium, temperature or speedsubject as dilution, conditions, method.settings
One "general" value where the source gives several by product type or pHseveral properties with scope or conditions
SPF published against the raw materialtie it to the test formulation
Concentration without saying of whatmaterial_conc.basis: as_supplied, active or total_solids
Numbers read off your own graph by eyepublish the raw series, or mark the figure as having no data
Only the positive endpoints of a studyall endpoints, with outcome
Certificate without validityvalid_from, valid_until
Today's date as as_of on five-year-old test datathe date of the test
Batch values from a certificate of analysisleave them out; a dossier is not batch data
A key that does not exist, slightly misspelledcheck vocab/; for a genuinely new key use x-yourdomain.com:name and propose it
Text in a number field ("n/a", "-")leave the element out
Instructions or links in free textplain sentences; consumers strip and escape them anyway
Editing a published versionnew version

8. Conformance checklist

Run .venv/bin/python tools/check_dossier.py path/to/your-dossier.json from the repository root (setup: README, "Checking a dossier"); it reports the level your dossier reaches and what is missing for the next one.

Level 1 — Core

  • Valid against the schema; all keys in the vocabularies.
  • identity: trade name, product code, manufacturer, INCI.
  • One general recommended use.level with an upper bound.
  • At least one use.phase (water phase, oil phase, cool-down, added to the hot water phase, added to the hot oil phase), or cold_process for a material that is processed only without heating.
  • Recommended: use.level_typical, use.ph_window, use.process_temperature_max, a few guidance lines.
  • Every element has id and as_of.
  • Listed in your index with its hash.

Level 2 — Technical (the data sheet)

  • Level 1.
  • composition: every component with role and content.
  • At least one profile.function and the profile.physical_form.
  • The specification: at least three properties with basis specification or typical (in practice: all rows of your specification table).
  • stability.shelf_life or stability.retest_period.
  • Regulatory status for at least one region as an attestation.
  • The SDS referenced as a source document.
  • Certificates with validity dates and usage restrictions.
  • Graphs present at least as figures, marked points_origin: "none" when without data.

Level 3 — Complete (replaces the brochure)

  • Level 2.
  • Every graph has its numeric (or ordinal) series.
  • No value exists only in a figure.
  • Every study: laboratory, number of subjects, at least one structured result, all_endpoints_reported: true.
  • Every efficacy result states whether it was significant.
  • declarations.negative_results_included: true.
  • completeness: "full".
  • Sunscreen and efficacy results tied to fully described test formulations.